University of Limerick Institutional Repository

Validation of ultrasound measurement of the subacromial space using a novel shoulder phantom model

DSpace Repository

Show simple item record

dc.contributor.author McCreesh, Karen
dc.contributor.author Adusumilli, Pratik
dc.contributor.author Evans, Tony
dc.contributor.author Riley, Sara
dc.contributor.author Davies, Andrew
dc.contributor.author Lewis, Jeremy S.
dc.date.accessioned 2019-04-11T15:21:36Z
dc.date.available 2019-04-11T15:21:36Z
dc.date.issued 2014
dc.identifier.uri http://hdl.handle.net/10344/7760
dc.description peer-reviewed en_US
dc.description.abstract Ultrasound has a high degree of diagnostic accuracy in the assessment of rotator cuff tendons. Increasingly, ultrasound is being used to measure other parameters of rotator cuff pathology, including the size of the subacromial space, or acromiohumeral distance (AHD). Although this measure has been found to be clinically reliable, no assessment of its validity has been carried out. This technical study reports on the development of a novel ultrasound phantom of the shoulder and its use in validation of ultrasound measurement of AHD. There was a close agreement between AHD measures using ultrasound and the true subacromial space of the phantom model, providing support for the construct validity of this measurement. The phantom model has good potential for further development as a training tool for shoulder ultrasound and guided injections. en_US
dc.language.iso eng en_US
dc.publisher Elsevier en_US
dc.relation.ispartofseries Ultrasound in Medicine and Biology;40 (7), pp. 1729-1733
dc.relation.uri https://doi.org/10.1016/j.ultrasmedbio.2013.12.015
dc.rights This is the author’s version of a work that was accepted for publication in Ultrasound in Medicine and Biology. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Ultrasound in Medicine and Biology, 2014, 40 (7), pp. 1729-1733, https://doi.org/10.1016/j.ultrasmedbio.2013.12.015 en_US
dc.subject ultrasound phantom en_US
dc.subject shoulder en_US
dc.subject acromiohumeral distance en_US
dc.title Validation of ultrasound measurement of the subacromial space using a novel shoulder phantom model en_US
dc.type info:eu-repo/semantics/article en_US
dc.type.supercollection all_ul_research en_US
dc.type.supercollection ul_published_reviewed en_US
dc.date.updated 2019-04-11T15:14:07Z
dc.identifier.doi 10.1016/j.ultrasmedbio.2013.12.015
dc.rights.accessrights info:eu-repo/semantics/openAccess en_US
dc.internal.rssid 1559389
dc.internal.copyrightchecked Yes
dc.identifier.journaltitle Ultrasound In Medicine And Biology
dc.description.status peer-reviewed


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search ULIR


Browse

My Account

Statistics