University of Limerick Institutional Repository

A validation study of a polymer optical fiber sensor for monitoring lumbar spine movement

DSpace Repository

Show simple item record

dc.contributor.author Kam, Wern
dc.contributor.author O'Keeffe, Mary
dc.contributor.author O'Sullivan, Kieran
dc.contributor.author Mohammed, Waleed S.
dc.contributor.author O'Keeffe, Sinéad
dc.contributor.author Lewis, Elfed
dc.contributor.author Viphavakit, Charusluk
dc.date.accessioned 2019-03-14T11:54:48Z
dc.date.available 2019-03-14T11:54:48Z
dc.date.issued 2019
dc.identifier.uri http://hdl.handle.net/10344/7696
dc.description peer-reviewed en_US
dc.description.abstract This study aims to investigate the validity and reliability of a novel plastic optical fiber (POF) sensor, which was developed to measure the angles of flexion, extension and lateral bend at the lumbar region. The angles of flexion, extension and lateral bend for a standing position were measured simultaneously using both the novel POF sensor of this investigation and the commercial Biometrics goniometer instrument. Each movement had two steps of bending which were 10 and 20 based on inclinometer readings. The POF sensor had good intra-rater reliability (Intraclass correlation coefficient, ICC = 0.61 to 0.83). Bland–Altman plots were used to study the agreement using these two sensors. There were proportional differences and bias between the POF sensor and Biometrics goniometer, as the zero points did not lie in the percentage difference region in the Bland–Altman plots. The proportional difference between these two likely reflects the different sizes and thus, measurement regions of the two sensors. There was also strong correlation between the two sensors (r > 0.77). Hence, the POF sensor could be of potential utility in measuring lumbar range of motion (ROM) in a manner which is minimally invasive, and where discrete sections of the spine are under specific investigation. en_US
dc.language.iso eng en_US
dc.publisher MDPI en_US
dc.relation.ispartofseries Materials;12, 762
dc.relation.uri http://dx.doi.org/10.3390/ma12050762
dc.subject plastic optical fibre sensor en_US
dc.subject range of motion en_US
dc.subject lumbar spine movement en_US
dc.title A validation study of a polymer optical fiber sensor for monitoring lumbar spine movement en_US
dc.type info:eu-repo/semantics/article en_US
dc.type.supercollection all_ul_research en_US
dc.type.supercollection ul_published_reviewed en_US
dc.identifier.doi 10.3390/ma12050762
dc.contributor.sponsor ERC en_US
dc.relation.projectid 2014-0855 en_US