University of Limerick Institutional Repository

Investigation into three dimensional ultrasound for generating vascular reconstructions suitable for diagnostic technique development

DSpace Repository

Show simple item record

dc.contributor.advisor McGloughlin, Timothy M.
dc.contributor.advisor Doyle, Barry J.
dc.contributor.author Gaughan, Sarah
dc.date.accessioned 2014-09-24T10:48:48Z
dc.date.available 2014-09-24T10:48:48Z
dc.date.issued 2014
dc.identifier.uri http://hdl.handle.net/10344/4031
dc.description peer-reviewed en_US
dc.description.abstract A three dimensional ultrasound (3DUS) system was developed with the aim of generating three dimensional (3D) vascular reconstructions. The system was required to be compatible with both a linear and a curvilinear transducer. A number of vascular phantoms were designed to recreate both shallow and deep vessels. A wall-less phantom with an agar based tissue mimicking material (TMM) and a cavity was found suitable for basic, shallow geometries. An idealised aneurysm with a silicone vessel mimicking material (VMM) represented a deeper, more complex geometry. Image processing to improve the boundary definition was found to have an insignificant effect on the images and may be unnecessary in this application. A NDI (Northern Digital Inc., Ontario, Canada) Polaris optical tracking system and the software Stradwin were combined to form ultrasound data that was tracked through three-dimensional space. The straight tube, wall-less phantom was used to test the method with a L14-5 transducer. Three reconstructions were made and the average percentage error in radius was less than 4.5%. As it is predominantly a manual method, a user variability study, using the ideal aneurysm phantom was conducted with three operators. This comprised of the operators each taking three scans which were processed by a single individual. Four profile lines were created on each reconstruction in four anatomical positions and the asymmetry of each line, in relation to a straight line, was calculated. The highest error found was 5.17mm. Three scans taken by one operator were then processed by three operators. In this case, the highest error found was 3.22mm. The user variability was not significant, however, it was discovered that all scans overestimated dimensions and were aligned at an angle. This angle was consistent for the calibration. It was found that the application of trigonometric functions to the data rectified these issues. When the angular error of 11º was corrected, the average error in diameter reduced from 22.1% to 8.1%. The cases with 45º reduced the error from 15% to 13.5%. In one case the error increased from 11.6% to 15.8% as the technique over corrected the issue. The correction factor’s success is dependent on the angle. Overall the results indicate 3DUS provides successful reconstructions using a linear transducer and has potential with a curvilinear transducer in a laboratory setting. en_US
dc.language.iso eng en_US
dc.publisher University of Limerick en_US
dc.subject three dimensional ultrasound system en_US
dc.subject 3DUS en_US
dc.subject image processing en_US
dc.subject vascular reconstruction en_US
dc.title Investigation into three dimensional ultrasound for generating vascular reconstructions suitable for diagnostic technique development en_US
dc.type info:eu-repo/semantics/masterThesis en_US
dc.type.supercollection all_ul_research en_US
dc.type.supercollection ul_published_reviewed en_US
dc.type.supercollection ul_theses_dissertations en_US
dc.rights.accessrights info:eu-repo/semantics/openAccess en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search ULIR


Browse

My Account

Statistics