dc.description.abstract In this paper, we present a series of experimental results of tracking an embedded sensor object similar in physical characteristics to telemetry capsules in the gastro-intestinal (GI) tract using radio frequency (RF) signals. A fair description of implementation detail is given in the body of the paper while focus is on analyzing the experimental results. Experiments were based on a test capsule transmitting radio frequency (RF) signals pulses at 433MHz; a Receiver based on microcontroller circuits with ADC capability and a means of transferring the received signal strength intensity (RSSI) voltage converted to digital, from the microcontroller to the personal computer (PC). Primary focus is a unique and practical way of achieving the task of dynamically identifying the location of the capsule in real-time as it traverses the experimental duct. Tracking results for experiments in liquid simulating the electrical behavior of the lower portion of the intestines yielded an average error of about 18.9%. These results were validated with the Bland-Altman plots using manual measurements as gold standard. Overall analysis shows that the end result of the algorithm is quite suitable for tracking ingestible telemetry capsules in the GI tract. en_US
dc.description.sponsorship EI
dc.language.iso eng en_US
dc.publisher IEEE Computer Society en_US
dc.relation.ispartofseries SAS;
dc.rights ©2008 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other users, including reprinting/ republishing this material for advertising or promotional purposes, creating new collective works for resale or redistribution to servers or lists, or reuse of any copyrighted components of this work in other works. en_US
dc.subject trilateration wireless endoscopy en_US
dc.subject real-time en_US
dc.title Tracking wireless bio-medical sensors:result validation with the bland-altman plots en_US
dc.type Conference item en_US
dc.type.supercollection all_ul_research en_US
dc.type.supercollection ul_published_reviewed en_US
dc.type.restriction none en

Files in this item

This item appears in the following Collection(s)

Show simple item record

Related Items

Search DSpace


Advanced Search

Browse

My Account